Determining the Wear Resistance of Occlusal Splints in a Prospective Clinical Study

Language: English

Authors: Dr. med. dent. Peter Ottl, Dentist Petra Schmelz, Dr. med. dent. Andree Piwowarczyk, Prof. Dr. med. dent. Hans-Christoph Lauer
Department of Prosthodontics, School of Dentistry, ZZMK (Carolinum), J. W. Goethe University, Frankfurt, Germany

Date/Event/Venue: 
May 17-19, 2001
50th Annual Meeting of the "Deutsche Gesellschaft für Zahnärztliche Prothetik und Werkstoffkunde"
Bad Homburg, Germany


Best Poster of Conference

Objective

To determine quantitatively the wear resistance of a newly developed light-curing splint resin over a period in situ of six months. 


Materials and Methods

  • Patients:
    n=20 consecutive patients (mean age: 34.7 years; 12 F, 8 M)

  • Inclusion criteria:
    • Natural dentition/fixed denture
    • Complete dentition to at least the 1st molar

      and

      for the stabilization splint sample:
    • Insufficient occlusal support
    • Increased occlusal loss of dental hard tissue

      for the distraction splint sample:
    • TMJ pain and
    • Complete anterior dislocation of the disk without reduction/with terminal reduction
    • TMJ osteoarthrosis

 

Fig. 1: Stabilization splint in situ

  • Resin splint material (Fig. 1):
    • Light-curing (400-500 nm) resin made of high-molecular dimethacrylates with organic and inorganic fillers
    • Does not contain methyl methacrylate

 

  • Study design:
    • Duration: 6 months
    • Types of splints (maxilla, n=10 each):
      stabilization splints, distraction splints
    • Splint wear mode: 24 hours
    • Examinations:
      before insertion (BI), at 4 weeks (4W), at 3 months (3M), at 6 months (6M)
    • Occlusal adjustments were restricted to the time before 4W.
Fig. 2: Test setup

  • Measuring Technology (Fig. 2)
    • Vibration-isolated table framework
    • 3 translation stages (for directions x, y, and z) (DC-Motor) (PI, Waldbronn)
    • DV 4 stereomicroscope (Zeiss, Oberkochen)
    • WA 20 inductive displacement transducer/ Spider8 digital 8-channel measurement unit/ Catman 32 software V2.1 (HBM, Darmstadt)
    • Local coordinate storage for occlusal contacts during baseline measurements
    • Ten measurements each in regions 13, 23, 16, 26 (BI, 4W, 3M, 6M)
    • Splint repositioned on remount cast

 

Results

  • The medians of the occlusal vertical gains/losses (wear, resin torsion, water sorption, etc.) are shown in Fig. 3 (stabilization splints) and Fig. 4 (distraction splints).
Fig. 3: Occlusal vertical gains/losses (medians) of the resin in vivo over a period in situ of six months (n=10 stabilization splints)


Fig. 4: Occlusal vertical gains/losses (medians) of the resin in vivo over a period in situ of six months (n=10 distraction splints)

  • Statistical analysis (Mann-Whitney U-test, p < 0.05) showed no significant differences when comparing the corresponding results of stabilization and distraction splints.
Figs. 5a and b: Sagittal oblique images (MRI) of the condyle/fossa relationship without splint (Fig. 5a) and with distraction splint inserted (Fig. 5b) following six months of wearing

Conclusions

  • The present study clinically confirms the good wear resistance results of the new resin splint material obtained in a previous in-vitro study [OTTL et al., Dtsch Zahnärztl Z 52, 342 (1997)].
  • Good wear resistance is of great importance for maintaining the therapeutic mandibular position during the treatment period (Figs. 5a and b).

 

This poster was submitted by Dr. Peter Ottl.